infrared-edge-sensor-fr-53
PRODUCT DESCRIPTION
Position-independent installation due to various mounting options such as flange bearings, pedestal bearings, inner or outer fastening
Maximum operational reliability due to overload protection up to 20 times the nominal measuring force
Different shaft diameters from 12 to 65 mm and nominal measuring forces from 0.05 to 10 kN ensure a high degree of flexibility
In case of horizontal measuring direction, no influence on the measuring result due to the weight of the roller
Good temperature behavior and a high degree of linearity of the measuring elements due to strain gauge application on a flat surface
| Accuracy class | 0,5 |
| Nominal characteristic (Sensitivity) | 1 m V/V |
| Combined error | < 0.5% |
| Characteristic value tolerance | 0.2% |
| Measuring principle | Full bridge strain gauge |
| Nominal resistance of the bridge strain gauge | 700 Ohm |
| Bridge supply voltage, nominal value | 10 V |
| Bridge supply voltage, max. permissible value | 14 V |
| Mechanical stop | 1.8 to 2.4 FN dep. on type |
| Operating load | 1.8 to 2.4 FN |
| Limit load | 20xFN |
| Nominal measuring travel | 0.1 to 0.2 mm depending on type |
| Nominal temperature range | -10 °C to +60 °C |
| Operating temperature range | -10 °C to +90 °C |
| Temperature coefficient | ±0.3% / 10 K (characteristic value) ± 0.3% / 10 K (zero signal) |
| Protection class | IP 50 |
| Max. permissible axial transverse force | 1xFN |
| Weight | 2.3 kg (d1 = 17 mm), 3.6 kg (d1 = 25 mm), 8.5 kg (d1 = 35 mm) |